R-YWC Series
Cyclic Salt Spray Chamber
Cyclic Salt Spray Chamber simulates outdoor conditions with salt mist and capable of accelerating corrosion on metallic materials. It includes a test method for cyclic exposure of samples to salt spray, dry, humidity and hot environments.
- Product Model:
- R-YWC Series
- Design Standard:
- MIL-STD-810, IEC61701, IEC60068-2-11, IEC60068-2-52, IEC60068-2-3, IEC 61215, ASTM B117, ISO 9227…
Description
Application:
Cylic Salt Spray Chamber is designed to simulate and enhance the effects of exposure to outdoor atmospheric conditions contaminated with salt and capable of accelerating corrosion on metallic materials. It includes a testing method for cyclic exposure of samples to salt fog, drying, humidity and heat environments.
The Corrosion Test Chamber is applicable to: metals and their alloys, metal coatings (anodic and cathodic), conversion coatings, anodic oxidation coatings, organic coatings on metallic materials, etc.
Specification:
| 01. Model | R-YWC-90 | |
| Volume | 270L | |
| Inner dimensions | W900*D600*H500mm | |
| Outer dimensions | W2100*D1100*H1400mm | |
| Weight | 400kg, Approx. | |
| Max. power & current | 9kW, 15A | |
| 02. Performance | ||
| Function | – Heating, Humidification, Dehumidification, Mist spray, Demist
– Reach set temperature, humidity and spray volume – Each function can be operated independently |
|
| Temperature range | 20℃ to +80℃ | |
| Humidity range | 20% to 100%R.H. | |
| Temp & humid range | ![]() |
|
| Resolution | Temperature 0.01℃, humidity 0.1%R.H | |
| Deviation | Temperature ≤±2℃, humidity ≤±3%R.H | |
| Uniformity | Temperature ≤±2℃, humidity ≤±3%R.H (>75%RH) & ±5%R.H (<75%RH) | |
| Fluctuation | Temperature ≤±0.5℃, humidity ≤±2%R.H | |
| Temperature change rate | – Ambient → +85℃≤40 min
– Ambient → 10℃≤30 min – Mist spray (35℃) → Dry (60℃@20~30%RH) ≤30 min – Dry (60℃@20~30%RH) → Damp heat (50℃@95%±5%RH) ≤15 min – Damp heat (50℃@95%±5%RH) → Salt mist (35℃) ≤30 min |
|
| Test condition | Comply with cyclic salt spray test method:
salt spray test → dry heat test → damp heat test A, Salt spray test: NSS, AASS, CASS (1) NSS & AASS Test Temperature of test room: 35±1℃ Temperature of saturated air tank: 47±1℃ (2) CASS Test Temperature of test room: 47±1℃ Temperature of saturated air tank: 63±1℃ (3) Sedimentation: 1~2ml/80cm2/h (average value in 16 hours) (4) Spray pressure: 1.0±0.5 kg/cm2 (5) Brine concentration: 5%, or 5% + 0.26g copper chloride (CuCl2 2H2O), (6) PH value: neutral test 6.5~ 7.2, Acid test 3.0~ 3.3 (7) Sample place angle: 15° to 30° B, Dry Heat Test (1) Temperature: 60±2℃ (2) Humidity: RH≤30% C, Damp Heat Test (1) Temperature: 23±2℃; humidity: 50%±5% (2) Temperature: 40±2℃; humidity: 93%±3% (3) Temperature: 50±2℃; humidity: ≥98% |
|
| 03. Structure | ||
| Chamber material | PP polypropylene board, thickness 1.0mm, temperature resistance 100℃ | |
| Chamber lid | – PP polypropylene board, thickness 1.0mm, temperature resistance 100℃;
– Driven by pneumatic cylinders, with transparent observation window |
|
| Humidity water reservoir | – Material: PP polypropylene plate;
– External humidification water tank with water level gauge; – Water inlet is equipped with purifier which can effectively filter impurities. |
|
| Saturated barrel | – PP material
– The compressed air passes through the air saturation generator, which is fully exchanged and filtered with distilled water to make the air reach the saturated steam state, so as to obtain moist and clean compressed air – Temperature balance is guaranteed by adjusting the temperature of the air saturation generator – Equipped with heating and temperature control system, and automatic water supply system |
|
| Top of inner chamber | Cone shape to effectively prevent water droplets from dropping onto test sample | |
| Pressure balance port | – Located on the rear of the chamber
– Effectively prevent the pressure difference inside chamber from affecting the uniform distribution of salt mist |
|
| Heating system | Titanium alloy heater, and circulating fan for strong air supply and circulation, and P.I.D controls the heating amount to achieve temperature balance | |
| Humidity system | Water vapor humidification method is adopted, compressor for dehumidification, and P.I.D controls the humidification amount to reach the required humidity. | |
| Air circulation system | Air duct: specially designed sealed damper device can automatically switch salt spray or temperature and humidity test | |
| Sample rack | – Material: PVC
– The angle of test sample can be 15° and 30°, salt mist falls on all sides uniformly |
|
| 04. Mist Spray & Demist System | ||
| Spray method | – Adopt Bernoult principle to absorb salt water and then atomize it.
– Atomization is uniform and no blocking crystallization phenomenon to ensure continuous and periodic testing. – Set automatic spray according to program |
|
| Defog | – Compressed air is charged into working chamber to remove the fog;
– Set automatic defog as per program |
|
| Spray nozzle | 2pcs glass nozzle, long time operation without crystal salt blocking | |
| Spray system | Salt spray sedimentation collection system | |
| Salt mist collection | – 1 to 2 ml/hour/80cm2
– Conical funnel with a diameter of 100mm – With silicone hose at the bottom of the funnel and connect it to the outdoor measuring cylinder, which can check the spray amount in real time to ensure the test accuracy. |
|
| 05. Electric & Control System | ||
| Controller | – Touch screen programmable controller
– English & Chinese |
|
| Display function | – PV & SV of temperature and humidity
– Program number, segment, remaining time, cycle times and running time – Graphic curve display – Program editing screen, and 4 segments of temperature, humidity and time can be input on each page – Constant & program operation are available – Backlight is available – Screen display protection function |
|
| Data output | RS232 / 485 communication port | |
| Resolution | Temperature 0.01℃; time 0.1min; humidity 0.1%R.H | |
| Input | PT100 Platinum | |
| 06. Cooling & Dehumidification System | ||
| Compressor | Air-cooled compressor | |
| Evaporator | Finned tube heat exchanger | |
| Other configuration | Throttling device, oil separator, dry filter, refrigerant | |
| 07. Installation Requirement | ||
| Environment conditions | – Temperature: 5~30℃
– Relative humidity: 45%~80%RH – Pressure: 84~106kPa |
|
| Installation conditions | – Smooth ground; good ventilation; without strong vibration and electromagnetic around
– Without inflammable, explosive, corrosive material and dust – There should be enough space for chamber maintenance and operation. |
|
| Power supply | – Three phase, AC380V, 50Hz
– Power cable: 5 wires (live wire + zero wire + protective ground wire) – Protective ground wire ground resistance less than 4Ω – The user should provide air switch with current 23A for the chamber separately. |
|
| Air source | – Spray pressure range: 0.07~0.17Mpa
– User should prepare the compressed air source. |
|
| Accessory list | User manual x 1pc
Sample rack x 1 set Wet gauze x 5pcs PH test paper x 1 bag Air pipe x 1pc |
Fog exhaust pipe x 1pc
Sealing plug x 2pcs Spray nozzle x 2pcs Measuring cup x 1pc Graduated cylinder x 2pcs |